High Sensitivity Water Meter Level

+
  • image/高灵敏水表水平DN15.jpg
  • image/高灵敏水表立式DN20.jpg
  • image/高灵敏水表.jpg

Functional Features

High sensitivity water meter level DN15 The installation dimensions of this water meter are completely consistent with ordinary water meters, making installation and maintenance convenient;

High sensitivity water meter level DN15 High reliability, resistant to rust and impurities, the main pipeline has the same magnetic field and usage conditions as ordinary water meters;

High sensitivity water meter level DN15 Strong adaptability to water pressure, with a wide working pressure range;

High sensitivity water meter level DN15 Starting flow as low as 1L/h, basically achieving drip measurement. Overall performance exceeds the requirements for level 2 water meters in the GB/T778-2007 standard;

High sensitivity water meter level DN15 This series of water meters is used for measuring the amount of drinking cold water flowing through household tap water pipelines.

Main Technical Parameters

Model

Nominal Diameter
(DN)

Q3/ Q1

Overload Flow
( Q4)

Common Flow
( Q3)

Boundary Flow
( Q2)

Minimum Flow
( Q1)

Minimum Reading

Maximum Reading

 

mm

 

m³∕h

m³

LXS-15

15

80

3.1

2.5

0.050

0.031

0.0001

99999

LXS-20

20

80

5

4.0

0.080

0.050

0.0001

99999

LXS-25

25

80

7.8

6.3

0.126

0.79

0.0001

99999

Indication Error

High sensitivity water meter level DN15 From including the minimum flow (Q1) to excluding the boundary flow (Q2) low zone ±5%

High sensitivity water meter level DN15 From including the boundary flow (Q2) to including the maximum flow (Q4) high zone ±2%

Operating Environment

High sensitivity water meter level DN15 Working water temperature: cold water meter 0~30℃

High sensitivity water meter level DN15 Working pressure: not exceeding 1MPa