Electronic Remote Reading Water Meter

+
  • 0(1244).jpg
  • 电子远传水表--LXSXY-20.jpg

Technical Parameters

1. Execution Standard: GB/T78.1~3-2018 "Measurement of Water Flow in Closed Full Pipelines for Drinking Cold Water Meters and Hot Water Meters"; CJ/T2242012 "Electronic Remote Water Meter";

2. Working Pressure: ≤1MPa;

3. Measured Water Temperature: Cold Water Meter 0~30℃, Hot Water Meter 0~90℃;

4. Electrical Parameters: Working Voltage: DC12V (RS485); DC24-42V (M-BUS) Maximum Current: I≤18mA; Communication Method with Upper Computer;

a) RS-485 Fieldbus;

b) M-BUS Fieldbus;

Communication Transmission Rate: 1200/2400 baud, Maximum Communication Transmission Distance: 1200m;

Lightning Protection Parameters: Bus Pin ESD Protection Exceeds 10kV;

5. Accuracy Level and Flow Range:

Model

Nominal Diameter
(DN)

Q3/ Q1

Overload Flow
( Q4)

Common Flow
( Q3)

Boundary Flow
( Q2)

Minimum Flow
( Q1)

Minimum Reading

Maximum Reading

 

mm

 

m³/h

m³

LXS-15

15

80

3.1

2.5

0.050

0.031

0.0001

99999

160

3.1

2.5

0.025

0.016

LXS-20

20

80

5

4.0

0.080

0.050

0.0001

99999

160

5

4.0

0.040

0.025

LXS-25

25

80

7.8

6.3

0.126

0.079

0.0001

99999

160

7.8

6.3

0.063

0.040

LXS-40

40

80

20

16

0.320

0.200

0.0001

99999

LXS-50

50

80

31.25

25

0.500

0.312

0.0001

99999

Indication Error

Electronic Remote Water Meter From including the minimum flow (Q1) to excluding the boundary flow (Q2) of the low zone ±5%

Electronic Remote Water MeterFrom including the boundary flow (Q2) to including the maximum flow (Q4) of the high zone ±2%