Check valve water meter level

+
  • image/止回阀水表水平DN15.jpg
  • z止回阀水表立式DN20.jpg

Functional Features

Check Valve Water Meter Level DN15 This water meter mainly adds a check valve at the inlet based on the original rotary vane cold water meter to prevent backflow of water in the pipeline. This water meter has a novel design, compact and reasonable structure, does not change the original appearance and size of the water meter, and can effectively prevent backflow caused by design defects in the pipeline, as well as effectively prevent water loss to the water supply company due to reverse installation of the water meter.

Check Valve Water Meter Level DN15 The check valve closes during reverse installation.

Check Valve Water Meter Level DN15 Optional wet water meter, dry water meter, hot water meter, etc.

Main Technical Parameters

Model

Nominal Diameter
(DN)

Q3/ Q1

Overload Flow Rate
( Q4)

Common Flow Rate
( Q3)

Boundary Flow Rate
( Q2)

Minimum Flow Rate
( Q1)

Minimum Reading

Maximum Reading

 

mm

 

m³∕h

LXS-15

15

80

3.1

2.5

0.050

0.031

0.0001

99999

160

3.1

2.5

0.025

0.016

LXS-20

20

80

5

4.0

0.080

0.050

0.0001

99999

160

5

4.0

0.040

0.025

LXS-25

25

80

7.8

6.3

0.126

0.079

0.0001

99999

160

7.8

6.3

0.063

0.040

Indication Error

Check Valve Water Meter Level DN15 From including the minimum flow rate (Q1) to excluding the boundary flow rate (Q2) in the low zone ±5%.

Check Valve Water Meter Level DN15 From including the boundary flow rate (Q2) to including the maximum flow rate (Q4) in the high zone ±2%.

Operating Environment

Check Valve Water Meter Level DN15 Working Water Temperature: Cold Water Meter 0~ 30℃

Check Valve Water Meter Level DN15 Working Pressure: Not exceeding IMPa