Ultrasonic Water Meter

+
  • s03.jpg

Product Introduction

The ultrasonic water meter is an intelligent integrated large-caliber water meter designed using ultrasonic technology, capable of detecting extremely low starting flow rates. Equipped with a built-in stainless steel filter, the ultrasonic water meter's extremely low starting flow rate will save users a significant amount of extra costs.

Working Principle

The dual-channel can be imagined as two swimming lanes, where person A and person B swim towards each other from their respective lanes at the same time. Assuming there is a constant water flow in the lane: A swims with the current, while B swims against it. The time difference when they touch the wall is proportional to the speed of the water flow. By repeatedly swimming, an accurate average water flow speed can be obtained, and the precise water flow speed multiplied by the constant cross-sectional area will yield an accurate flow value.

Functional Features

Ultrasonic Water Meter Dual-channel acoustic ring method, accurate and reliable measurement.

Ultrasonic Water Meter Extremely low starting flow rate down to 25L.

Ultrasonic Water Meter Actual range ratio over 500.

Ultrasonic Water Meter Protection level IP68.

Ultrasonic Water Meter Battery powered, with a working life of over ten years.

Ultrasonic Water Meter No front and back pipeline requirements U0/D0.

Ultrasonic Water Meter Alarm and statistical functions.

Ultrasonic Water Meter Large LCD display with rich content: flow direction, instantaneous flow, cumulative flow, different units, etc.

Ultrasonic Water Meter Reserved automatic meter reading and network monitoring interfaces.

Ultrasonic Water Meter Can set forward and reverse water flow dual pulse output or 4-20mA instantaneous flow output.

Technical Parameters

Nominal Caliber

DN

mm

40

50

50*

80

100

150

200

250

300

Common Flow Rate

Q3

m³/h

40

40

40

63

100

250

400

1000

1000

Range Ratio

Q3/Q1

 

250

500

500

500

500

500

500

500

500

 

 

 

667

667

667

787.5

1000

625

500

500

500

 

Q2/Q1

 

1.6

1.5625

1.5625

1.6

1.6

1.6

1.6

1.6

1.6

 

 

 

2

2

2

2.5

3.2

1.5

1.25

1.6

1.6

Overload Flow Rate

Q4

m³/h

50

50

50

80

125

313

500

1250

1250

 

 

m³/h

65

65

65

100

150

320

510

1250

1250

Boundary Flow Rate

Q2

m³/h

0.256

0.125

0.125

0.200

0.320

0.800

1.280

3.2

3.2

 

 

m³/h

0.125

0.125

0.120

0.200

0.320

0.600

1.000

3.2

3.2

Minimum Flow Rate

Q1

m³/h

0.16

0.080

0.080

0.125

0.200

0.500

0.800

2

2

 

 

m³/h

0.060

0.060

0.060

0.080

0.100

0.400

0.800

2

2

Starting Flow Rate

 

m³/h

0.025

0.025

0.025

0.025

0.025

0.200

0.200

0.500

0.500

Maximum Peak Flow Rate

 

m³/h

65

75

-

120

200

350

550

-

-